Wednesday, May 2, 2012

Noisy PVC Vent Pipes


Our new house was built with a high efficiency furnace and hot water heater. Both were vented with 2" PVC pipe. Unfortunately the pipes were hung with "normal" drain-waste-vent (DWV) "J hooks" like the ones you find at the "big box" stores. These hangers were not intended for use with venting systems that see large temperature swings. Consequently the hanger/pipe connections make a lot of noise as the pipes heat up and then cool off.  The hangers are attached to the joists of the floor above which makes the house structure a "sounding board" for the connection noise. I even contacted the manufacturer of our original "J hooks" and they said their product was not approved for this use!

Fortunately there is a good answer if you still have physical access to the "J hooks". Warwick Hanger makes a great "J hook" with a hinged top piece so that they are not "spring loaded" around the PVC pipe. It's called the "Glide Lock J Hook" . I purchased a box of these and then lined most of the surface of the "J hook" that touches the PVC pipe with self-adhesive felt. Then I replaced all of the "normal J hooks" with the new ones. And that is the end of the noisy PVC vent pipes.